Worcester Greenskies FK240 Solar Panel

Operation

Worcester Greenskies FK240 Solar Panels form part of a system which remains separate from the boiler heating system.

The panels are mounted on a surface which is selected for its exposure to sunlight and usually connected, via pipe work, to the lower coil of a twin-coil solar cylinder. The energy in the sun’s rays is absorbed by the panel and the heat is transferred into the pipe work in the absorber plates. The pipe work is filled with a ready-mixed liquid, containing glycol and water, which is circulated by a pump to the coil in the hot water cylinder. The heat is deposited in the storage cylinder and the glycol returns to the panel to absorb more free solar energy. The system is equipped with a simple unit to control the flow of energy from the panels to the storage cylinder.

Greenskies Operation Diagram

Technical data table

Classification Worcester Greenskies FK240 Solar Panel
Panel height 112mm
Panel width 1,135mm
Panel length 2,115mm
Weight (empty) 43kg
Fluid content 1.15 litres
Gross surface area 2.4m2
Net surface area 2.1m2
Stagnation temperature 181ºC
Max operation pressure 3 bar
Min efficiency 525 kWh/m2a
Absorption 92%
Emission 12%
Glycol freezing temperature -38ºC
Max collectors in series 9