What is the single most important subject, that this generation of the worlds mothers and fathers, should be teaching their children about?
Worcester Greenskies FK240 Solar Panel
Operation
Worcester Greenskies FK240 Solar Panels form part of a system which remains separate from the boiler heating system.
The panels are mounted on a surface which is selected for its exposure to sunlight and usually connected, via pipe work, to the lower coil of a twin-coil solar cylinder. The energy in the sun’s rays is absorbed by the panel and the heat is transferred into the pipe work in the absorber plates. The pipe work is filled with a ready-mixed liquid, containing glycol and water, which is circulated by a pump to the coil in the hot water cylinder. The heat is deposited in the storage cylinder and the glycol returns to the panel to absorb more free solar energy. The system is equipped with a simple unit to control the flow of energy from the panels to the storage cylinder.
Technical data table
| Classification | Worcester Greenskies FK240 Solar Panel |
|---|---|
| Panel height | 112mm |
| Panel width | 1,135mm |
| Panel length | 2,115mm |
| Weight (empty) | 43kg |
| Fluid content | 1.15 litres |
| Gross surface area | 2.4m2 |
| Net surface area | 2.1m2 |
| Stagnation temperature | 181ºC |
| Max operation pressure | 3 bar |
| Min efficiency | 525 kWh/m2a |
| Absorption | 92% |
| Emission | 12% |
| Glycol freezing temperature | -38ºC |
| Max collectors in series | 9 |